We are getting asked more and more frequently about how efficient heat pumps really are. There is no straightforward answer, as performance depends on many factors, with one of the biggest being COP (Coefficient of Performance).
Boiler Efficiency & Traditional Heating Systems
A correctly set up modern condensing gas or oil boiler, especially with proper commissioning, combustion settings and the correct flow/return delta T, can achieve very high efficiency, often approaching around 98% under ideal condensing conditions. Heating oil has a calorific value of roughly 10.8kWh per litre, meaning most of that stored energy can be converted into usable heat when the appliance is operating correctly.
Gas systems are similar, and in real-world terms, both fuels remain highly effective for high-temperature heating, particularly in older properties or systems designed around traditional radiator outputs. Boiler efficiency ultimately depends heavily on setup, return temperatures and whether the appliance is genuinely condensing during operation.
How Air Source Heat Pumps Work
An Air Source Heat Pump works differently because it moves heat rather than creates it. Its efficiency is measured using the Coefficient of Performance (COP), where a COP of 4 means 1kWh of electricity produces 4kWh of heat. However, those higher COP figures are generally only achievable in milder weather and on low-temperature systems such as underfloor heating or oversized radiators.
During colder winter months, especially for retrofit radiator systems that require higher flow temperatures, real-world COP can drop much lower, often to 1–2, effectively yielding around 100–200% efficiency. Once outdoor temperatures drop, and system demand increases, many ASHP systems will rely more heavily on built-in immersion or backup electric heaters to maintain required temperatures, at which point efficiency effectively drops to near 100% as electricity is directly converted into heat.
If a property loses heat faster than the heat pump can replace it, indoor temperatures may gradually fall, resulting in a noticeably cooler home compared to a traditional gas or oil heating system, which can maintain consistently higher flow temperatures and recover heat more quickly.
Emitter Sizing & System Requirements
Emitter sizing is also a major consideration when moving to a heat pump system. If the property already has underfloor heating, this is generally considered an ideal setup for an ASHP because UFH operates at much lower flow temperatures, which is where heat pumps are most efficient. However, properties with smaller traditional radiators may require significant upgrades, including larger radiators, fan-assisted emitters, or even skirting heating systems, to deliver sufficient heat output at lower temperatures.
Pipework may also need attention, as heat pumps rely on moving a greater volume of water through the system than conventional boilers, which can mean older or undersized pipework can sometimes become a restriction.
Space Requirements for Heat Pump Installation
Space requirements should also be considered carefully before installation. Unlike a straightforward combi boiler replacement, an ASHP system requires external space for the outdoor unit and internal space for additional equipment, such as a hot water cylinder, buffer vessel, low-loss header, circulation pumps, and associated controls.
In some properties, this is easy to accommodate, while in others, available space can become a major factor in determining whether a heat pump installation is practical.
Air Source Heat Pump Running Costs
Cost is an area where ASHPs need particular care. On paper, especially once the Boiler Upgrade Scheme grant is included, an air source heat pump can appear to be a worthwhile investment. However, the hidden factor is the actual cost per kWh of heat produced.
Based on current UK price-cap figures, electricity is around 24.67p/kWh, while mains gas is around 5.74p/kWh. Heating oil is currently around £1.01 per litre, and with oil containing roughly 10.8kWh per litre, that works out at about 9.4p/kWh before boiler efficiency, or roughly 9.5–10p/kWh of usable heat once boiler performance is considered.
Why COP Matters for Running Costs
This means an ASHP has to achieve a decent COP just to compete on running costs. At COP 4, electricity at 24.67p/kWh gives heat at about 6.2p/kWh, which is cheaper than oil and closer to gas.
At COP 3, it is about 8.2 p/kWh, which is still reasonable. However, at COP 2, the heat cost rises to around 12.3p/kWh, and at COP 1, when backup immersion or direct electric heating is doing much of the work, it becomes the full 24.67p/kWh. This is why system design matters so much: a well-designed low-temperature system can be economical, but a poorly designed retrofit running at high flow temperatures in winter can quickly become more expensive than gas or oil to operate.
Common Heat Pump Installation Problems
Unfortunately, many systems are installed incorrectly or into properties that are simply not suited to low-temperature heating without further upgrades. Poor insulation, undersized emitters, incorrect heat loss calculations, poor controls setup, or incorrectly sized heat pumps can all massively impact performance.
An undersized heat pump may struggle to maintain indoor temperatures during colder weather, forcing backup electric heaters to run more frequently, while an oversized unit can short-cycle and operate inefficiently. Many homeowners are now experiencing unexpectedly high electricity bills because their systems are operating outside their ideal design conditions.
In many cases, the heat pump itself is not necessarily the issue; the problem is often poor system design, insufficient insulation levels or unrealistic expectations about how the property will perform compared to a traditional high-temperature gas or oil heating system.
If you are unsure whether an ASHP or GSHP system is suitable for your property, give us a call. We will run through the available options with you and provide honest, impartial advice based on your property and heating requirements.